• +86-769-82253316

+86-769-82253301

sandy@gl-leds.com

info@gl-leds.com

led video


RGB DMX 512 Controller

Mode: GL-CT-F

DMX 512 controller

Features

1.Operating temperature: -20-60 Celsius;

2.Supply voltage: DC12V, 24V;

3.Output: 3-loop;

4.Connection: Common Anode;

5.Connection Agreement: DMX512/1990;

6.Grayscale output: 256;

7.System Channels : 5CH (RGB light strip and water flow light strip )

8.Package size: 218*163*73mm;

9.Gross Weight: 473g;

10.Static power consumption: <1W;

11.Output Current: <6A (per loop);

12.Output Power: 12V<216W, 24V<432W.


The led controller uses microcomputer control chip, is used to control a variety of led lamps as the light source, adjusting color temperature of light, adjusting color temperature LED modules.DMX512/1990 using a standard protocol, with connection to facilitate the use of simple, convenient, centralized control etc.; according to the actual needs of the user the flexibility to select the required color temperature.

PROGRAM TABLE

Mode Effects Mode Effects
1 White 17 blue, purple, red, yellow, green, sky blue jump (fast)
2 Red 18 blue, purple, red, yellow, green, sky blue jump (slow)
3 Green 19 blue, purple, red, yellow, green, sky blue jump (slowest)
4 Blue 20 blue, purplw, red, yellow, green sky blue gradient (fastest)
5 Purple 21 blue, purplw, red, yellow, green sky blue gradient (fast)
6 Yellow 22 blue, purplw, red, yellow, green sky blue gradient (slow)
7 Sky Blue 23 blue, purplw, red, yellow, green sky blue gradient (slowest)
8 white, blue, purple, red, yellow, green, sky blue jump 24 single color chase forward like flow sater (fast)
9 white, blue, purple, red, yellow, green, sky blue jump (fast) 25 single color chase forward like flow sater (slow)
10 white, blue, purple, red, yellow, green, sky blue jump (slow) 26 single color chase reverse like flow sater (fast)
11 white, blue, purple, red, yellow, green, sky blue jump (slowest) 27 single color chase reverse like flow sater (slow)
12 white, blue, purple, red, yellow, green, sky blue gradient (fastest) 28 Colorful flashing jump (fast)
13 white, blue, purple, red, yellow, green, sky blue gradient (fast) 29 Colorful flashing jump (slow)
14 white, blue, purple, red, yellow, green, sky blue gradient (slow) 30 red green and blue flashing jump (fast)
15 white, blue, purple, red, yellow, green, sky blue gradient (slowest) 31 red green and blue flashing jump (slow)
16 blue, purple, red, yellow, green, sky blue jump (fastest)    

DMX Controller panel presentation:

DMX controller

Figure Schematic diagram of the sequence annotation of the: Dimmer1 dimming knob, Dimer2 dimming knob,Dimmer 3 dimming knob, six of the DIP switch, RGB-OUT terminal, POWER-INPUT terminals, 2 PCS DMX 512 port .

Instructions :

DMX Controller can be divided into three kinds of control mode:

1. Stand-alone use;

2. Multi-machine on-line use;

3. Through the use of DMX 512 Controller consoles.

Single Use

When used in stand-alone divided into: manual control and remote control.

rgb dmx controller

A. manual control

DMX 512 Controller has three dimmer knob is used to control LED brightness for each road.

Controller on the six DIP switches, which is used to manually adjust the built-in program, the sixth for host bits, in front of five dial code for the program number, do host the sixth dial code must be set aside.

Under its operation see the procedure list.

B. Remote control

When the dmx 512 controller requires a remote control, the controller of the sixth set of DIP "ON", at this time controller in a remote state. Remote control button fumctions as follows:

Multi-machine on-line access :

dmx controller

When you need to connect multiple machines, you can use DMX-IN, DMX-OUT interface for connect, detailed connection diagram is as follows:

In this system, need to set up a host of other machines is set to slave. Host set up and use as stand-alone. Set the first to the fifth dial code to the needed address number during use slave machines . Address number calculated by the following formula: Address Number = (No. 5 dial code) * 16 + (No. 4 dial code) * 8 + (No. 3 dial code) * 4 + (No. 2 dial code) * 2 + (the first one dial code) * 1; (No. N-bit dial code) represents the first N-bit dial code values, if the first N-bit dial code is set to OFF, value is 0, if the first N-bit dial code is set to ON, value is 1. For example: 1 = ( 0) * 16 + (0) * 8 + (0) * 4 + (0) * 2 + (1) * 1 10 = (0) * 16 + (1) * 8 + (0) * 4 + (1) * 2 + (0) * 1



The use of RGB DMX 512 console

DMX 512 Console








If you need to use DMX 512 control system , all of the controllers all the time as a slave to use, address number of settings same as Multi-machine on-line access, please refer to the address number from the above No 2 settings. Connection diagram is as left side:

Connection Instruction :

DMX 512 Controller If you need to use DMX 512 control system , all of the controllers all the time as a slave to use, address number of settings same as Multi-machine on-line access, please refer to the address number from the above No 2 settings. Connection diagram is as left side:Clear key: ON/OFF Key

ENTER Key: confirm key; confirm and run the currently selected program number,save the program number;

Remaining six number keys( key1 -key 6):

Through "Addition operation" to combine with any of the selected program number;For example: if needed to select program 10 (see all the programs in following program list.. Firstly. press the" CLEAR" key ,later press " key 4" and "key 6" ,then press" ENTER" Key to confirm this program and run it.. of course, press "key 5" twice also can get the program 10.

Note of DMX Controller :

>>lnstallation, try to avoid the minefields, strong magnetic field and high-pressure region.

>>Before useing DMX Controller Ensuring a solid connection correctly in order to avoid short-circuit damage to components and trigger fires.

>>RGB DMX 512 Controller is installed in a well-ventilated place to ensure appropriate environmental temperature.

>>Using thIs product, please check the local voltage, power adapter is in line with product requirements, whether the definition of positive and negative power supply and product line.

>>To prohibit the live wiring, check to DMX Controller confirm wiring is correct,check the no short-circuit,and then power!

>>ln case of failures, do not maintenance in private.


Contact Us
General lighting Electronic Co.,Ltd.
Tel: +86-769-82253316
Fax: +86-769-82253301
Mail: info@gl-leds.com
Web site: www.gl-leds.com
Address: F Building,Julong Industrial Park,Tianxin Meitang Community,Huangjiang Town,Dongguan,China
Feedback
Please click "Feedback" to leave your message and we'll reply you as soon as possible.
Certificate
led certificate

LED Light LED Tube LED Bulb LED Spotlight LED Panel light LED Strip LED Light Bar Contact GL

General lighting Electronic CO.,LTD. Copyright © 2010 . All rights reserved.General Lighting Electronic Co., Ltd. All rights reserved. No part of this photo may be reproduced, in any form or by any means, without permission inwriting from General Lighting Electronic Co. Ltd.
Top